Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 77.295
1.
Scand Cardiovasc J ; 58(1): 2347297, 2024 Dec.
Article En | MEDLINE | ID: mdl-38695238

Objectives. Atrial fibrillation is a common arrhythmia in patients with ischemic heart disease. This study aimed to determine the cumulative incidence of new-onset atrial fibrillation after percutaneous coronary intervention or coronary artery bypass grafting surgery during 30 days of follow-up. Design. This was a prospective multi-center cohort study on atrial fibrillation incidence following percutaneous coronary intervention or coronary artery bypass grafting for stable angina or non-ST-elevation acute coronary syndrome. Heart rhythm was monitored for 30 days postoperatively by in-hospital telemetry and handheld thumb ECG recordings after discharge were performed. The primary endpoint was the cumulative incidence of atrial fibrillation 30 days after the index procedure. Results. In-hospital atrial fibrillation occurred in 60/123 (49%) coronary artery bypass graft and 0/123 percutaneous coronary intervention patients (p < .001). The cumulative incidence of atrial fibrillation after 30 days was 56% (69/123) of patients undergoing coronary artery bypass grafting and 2% (3/123) of patients undergoing percutaneous coronary intervention (p < .001). CABG was a strong predictor for atrial fibrillation compared to PCI (OR 80.2, 95% CI 18.1-354.9, p < .001). Thromboembolic stroke occurred in-hospital in one coronary artery bypass graft patient unrelated to atrial fibrillation, and at 30 days in two additional patients, one in each group. There was no mortality. Conclusion. New-onset atrial fibrillation during 30 days of follow-up was rare after percutaneous coronary intervention but common after coronary artery bypass grafting. A prolonged uninterrupted heart rhythm monitoring strategy identified additional patients in both groups with new-onset atrial fibrillation after discharge.


Atrial Fibrillation , Coronary Artery Bypass , Percutaneous Coronary Intervention , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/epidemiology , Atrial Fibrillation/physiopathology , Atrial Fibrillation/etiology , Prospective Studies , Percutaneous Coronary Intervention/adverse effects , Male , Incidence , Female , Coronary Artery Bypass/adverse effects , Aged , Middle Aged , Risk Factors , Time Factors , Treatment Outcome , Coronary Artery Disease/surgery , Coronary Artery Disease/therapy , Coronary Artery Disease/diagnosis , Heart Rate , Angina, Stable/diagnosis , Angina, Stable/physiopathology , Angina, Stable/epidemiology , Angina, Stable/surgery , Angina, Stable/therapy , Risk Assessment , Acute Coronary Syndrome/therapy , Acute Coronary Syndrome/diagnosis , Acute Coronary Syndrome/surgery , Acute Coronary Syndrome/epidemiology , Telemetry
2.
Arq Bras Cardiol ; 121(3): e20230470, 2024.
Article Pt, En | MEDLINE | ID: mdl-38695466

BACKGROUND: Coronavirus disease 2019 (COVID-19) is associated with hypercoagulability. It remains uncertain whether ongoing anticoagulation for atrial fibrillation (AF) in patients who later contract COVID-19 improves clinical outcomes. OBJECTIVES: To compare chronic oral anticoagulation with no previous anticoagulation in patients with AF who contracted a COVID-19 infection concerning the outcomes of all-cause mortality, COVID-19 mortality, intensive care unit (ICU) admission, and hospitalization. METHODS: We systematically searched PubMed, Embase, and Cochrane Library for eligible studies from inception to December 2022. We included studies comparing COVID-19 outcomes in patients with versus without prior chronic anticoagulation for AF. Risk ratios (RR) with 95% confidence intervals (CI) were pooled with a random-effects model. The level of significance was set at p < 0.05. Quality assessment and risk of bias were performed according to Cochrane recommendations. RESULTS: Ten studies comprising 1,177,858 patients with COVID-19 and AF were identified, of whom 893,772 (75.9%) were on prior chronic anticoagulation for AF. In patients with COVID-19, being on chronic anticoagulation for AF significantly reduced all-cause mortality (RR 0.75; 95% CI 0.57 to 0.99; p = 0.048; I2 = 89%) and COVID-19-related mortality (RR 0.76; 95% CI 0.72 to 0.79; p < 0.001; I2 = 0%) when compared with no prior anticoagulation. In contrast, there was no difference between groups regarding hospitalization (RR 1.08; 95% CI 0.82 to 1.41; p = 0.587; I2 = 95%) or ICU admission (RR 0.86; 95% CI 0.68 to 1.09; p = 0.216; I2 = 69%). CONCLUSIONS: In this meta-analysis, chronic anticoagulation for patients with AF who contracted COVID-19 was associated with significantly lower rates of all-cause mortality and COVID-19-related mortality as compared with no previous anticoagulation.


FUNDAMENTO: A doença por coronavírus 2019 (COVID-19) está associada à hipercoagulabilidade. Permanece incerto se a anticoagulação contínua para fibrilação atrial (FA) em pacientes que posteriormente contraem COVID-19 melhora os desfechos clínicos. OBJETIVOS: Comparar a anticoagulação oral crônica com ausência de anticoagulação prévia em pacientes com FA que contraíram uma infecção por COVID-19 em relação aos desfechos de mortalidade por todas as causas, mortalidade por COVID-19, admissão em unidade de terapia intensiva (UTI) e hospitalização. MÉTODOS: Buscamos sistematicamente no PubMed, Embase e Cochrane Library estudos elegíveis desde o início até dezembro de 2022. Incluímos estudos que compararam desfechos de COVID-19 em pacientes com e sem anticoagulação crônica prévia para FA. Foram agrupadas razões de risco (RR) com intervalos de confiança (IC) de 95% por meio de um modelo de efeitos aleatórios. O nível de significância foi estabelecido em p < 0,05. As avaliações da qualidade e do risco de viés foram realizadas de acordo com as recomendações da Cochrane. RESULTADOS: Foram identificados 10 estudos abrangendo 1.177.858 pacientes com COVID-19 e FA, dos quais 893.772 (75,9%) estavam em anticoagulação crônica prévia para FA. Em pacientes com COVID-19, a anticoagulação crônica para FA reduziu significativamente a mortalidade por todas as causas (RR 0,75; IC 95% 0,57 a 0,99; p = 0,048; I2 = 89%) e a mortalidade relacionada à COVID-19 (RR 0,76; IC 95% 0,72 a 0,79; p < 0,001; I2 = 0%) quando comparada com a ausência de anticoagulação prévia. Em contrapartida, não houve diferença entre os grupos em relação à hospitalização (RR 1,08; IC 95% 0,82 a 1,41; p = 0,587; I2 = 95%) ou internação em UTI (RR 0,86; IC 95% 0,68 a 1,09; p = 0,216; I2 = 69%). CONCLUSÕES: Nesta metanálise, a anticoagulação crônica para pacientes com FA que contraíram COVID-19 foi associada a taxas significativamente mais baixas de mortalidade por todas as causas e mortalidade relacionada à COVID-19 em comparação com a ausência de anticoagulação anterior.


Anticoagulants , Atrial Fibrillation , COVID-19 , Humans , Atrial Fibrillation/drug therapy , Atrial Fibrillation/mortality , Atrial Fibrillation/complications , COVID-19/mortality , COVID-19/complications , Anticoagulants/therapeutic use , Anticoagulants/administration & dosage , Hospitalization/statistics & numerical data , SARS-CoV-2 , Intensive Care Units
3.
Arq Bras Cardiol ; 121(4): e20230544, 2024.
Article Pt, En | MEDLINE | ID: mdl-38695471

BACKGROUND: Ablation Index (AI) software has allowed better atrial fibrillation (AF) ablation results, but recurrence rates remain significant. Specific serum biomarkers have been associated with this recurrence. OBJECTIVES: To evaluate whether certain biomarkers could be used (either individually or combined) to predict arrhythmia recurrence after AI-guided AF ablation. METHODS: Prospective multicenter observational study of consecutive patients referred for AF ablation from January 2018 to March 2021. Hemoglobin, brain natriuretic peptide (BNP), C-reactive protein, high sensitivity cardiac troponin I, creatinine clearance, thyroid-stimulating hormone (TSH) and free thyroxine (FT4) were assessed for their ability to predict arrhythmia recurrence during follow-up. Statistical significance was accepted for p values of<0.05. RESULTS: A total of 593 patients were included - 412 patients with paroxysmal AF and 181 with persistent AF. After a mean follow-up of 24±6 months, overall single-procedure freedom from atrial arrhythmia was 76.4%. Individually, all biomarkers had no or only modest predictive power for recurrence. However, a TSH value >1.8 µUI/mL (HR=1.82 [95% CI, 1.89-2.80], p=0.006) was an independent predictor of arrhythmia recurrence. When assessing TSH, FT4 and BNP values in combination, each additional "abnormal" biomarker value was associated with a lower freedom from arrhythmia recurrence (87.1 % for no biomarker vs. 83.5% for one vs. 75.1% for two vs. 43.3% for three biomarkers, p<0.001). Patients with three "abnormal" biomarkers had a threefold higher risk of AF recurrence compared with no "abnormal" biomarker (HR=2.88 [95% CI, 1.39-5.17], p=0.003). CONCLUSIONS: When used in combination, abnormal TSH, FT4 and BNP values can be a useful tool for predicting arrhythmia recurrence after AI-guided AF ablation.


FUNDAMENTO: O software ablation index (AI) permitiu melhorar os resultados da ablação de fibrilação atrial (FA), mas as taxas de recorrência permanecem significativas. Biomarcadores séricos específicos têm sido associados a essa recorrência. OBJETIVOS: Avaliar se certos biomarcadores podem ser utilizados (individualmente ou combinados) para predizer a recorrência de FA pós ablação guiada pelo AI. MÉTODOS: Estudo multicêntrico, observacional, prospectivo de pacientes consecutivos, encaminhados para ablação de FA de janeiro de 2018 a março de 2021. Hemoglobina, peptídeo natriurético cerebral (BNP), proteína C reativa, troponina I ultrassensível, clearance de creatinina, Hormônio Tireoestimulante (TSH), e Tiroxina livre (T4) foram avaliados quanto à capacidade de prever a recorrência de arritmias durante o acompanhamento. Valores de p <0,05 foram aceitos como estatisticamente significativos. RESULTADOS: Um total de 593 pacientes foram incluídos ­ 412 com FA paroxística e 181 com FA persistente. Durante o seguimento médio de 24±6 meses, 76,4% não apresentaram recidiva após ablação. Individualmente, os biomarcadores demonstraram um valor preditivo baixo ou nulo para recorrência. No entanto, TSH >1,8 µUI/mL [HR=1,82 (IC95%, 1,89-2,80), p=0,006] foi um preditor independente de recorrência. Avaliando-se a combinação de TSH, FT4 e BNP, a adição de cada valor "anormal" foi associada a uma menor sobrevida livre de recorrência (87,1% se nenhum vs. 83,5% se um vs. 75,1% se dois vs. 43,3% se três biomarcadores, p<0,001). Doentes com três biomarcadores "anormais" apresentaram três vezes maior probabilidade de recorrência de FA, comparativamente aos que não apresentaram nenhum biomarcador "anormal" (HR=2,88 [IC95%, 1,39-5,17], p=0,003). CONCLUSÕES: Quando combinados, valores anormais de TSH, FT4 e BNP podem ser uma ferramenta útil para prever a recorrência de FA pós ablação guiada pelo AI.


Atrial Fibrillation , Biomarkers , Catheter Ablation , Recurrence , Thyrotropin , Humans , Atrial Fibrillation/surgery , Atrial Fibrillation/blood , Biomarkers/blood , Male , Female , Prospective Studies , Middle Aged , Catheter Ablation/methods , Aged , Thyrotropin/blood , Natriuretic Peptide, Brain/blood , Predictive Value of Tests , C-Reactive Protein/analysis , Treatment Outcome , Thyroxine/blood , Risk Factors , Troponin I/blood
4.
PLoS One ; 19(5): e0302517, 2024.
Article En | MEDLINE | ID: mdl-38722976

OBJECTIVES: Left atrial appendage occlusion during cardiac surgery is a therapeutic option for stroke prevention in patients with atrial fibrillation. The effectiveness and safety of left atrial appendage occlusion have been evaluated in several studies, including the LAAOS-III trial. While these studies have demonstrated efficacy and safety, the long-term economic impact of this surgical technique has not yet been assessed. Here, we aimed to evaluate the cost-effectiveness and cost-utility of left atrial appendage occlusion during cardiac surgery over a long-term time horizon. METHODS: Our study was based on a model representing an hypothetical cohort with the same characteristics as LAAOS-III trial patients. We modelled the incidence of ischemic strokes and systemic embolisms in each intervention arm: "occlusion" and "no-occlusion," using a one-month cycle length with a 20-year time horizon. Regarding occlusion devices, sutures, staples, or an approved surgical occlusion device (AtriClip™-AtriCure, Ohio, USA) could be used. RESULTS: Our model generated an average cost savings of 607 euros per patient and an incremental gain of 0.062 quality-adjusted life years (QALYs), resulting an incremental cost-utility ratio (ICUR) of €-9,775/QALY. The scenario analysis in which occlusion was systematically performed using the AtriClip™ device generated an ICUR of €3,952/QALY gained. CONCLUSIONS: In the base-case analysis, the strategy proved to be more effective and less costly, confirming left atrial appendage occlusion during cardiac surgery as an economically dominant strategy. The scenario analysis also appeared cost-effective, although it did not result in cost savings. This study provides a new perspective on the assessment of the cost-effectiveness of these techniques.


Atrial Appendage , Atrial Fibrillation , Cardiac Surgical Procedures , Cost-Benefit Analysis , Quality-Adjusted Life Years , Humans , Atrial Appendage/surgery , Cardiac Surgical Procedures/adverse effects , Cardiac Surgical Procedures/economics , Cardiac Surgical Procedures/methods , Atrial Fibrillation/surgery , Atrial Fibrillation/economics , France , Male , Female , Stroke/prevention & control , Stroke/economics , Stroke/etiology , Aged
5.
BMJ Open ; 14(5): e079881, 2024 May 09.
Article En | MEDLINE | ID: mdl-38724059

OBJECTIVES: Pulsed field ablation (PFA) is a promising new ablation modality for the treatment of atrial fibrillation (AF) that has recently become available in the UK National Health Service (NHS). We provide the first known economic evaluation of the technology. METHODS: A cost-comparison model was developed to compare the expected 12-month costs of treating AF using the pentaspline PFA catheter compared with cryoablation for a single hypothetical patient. Model parameters were based on a recent cost-effectiveness analysis by the National Institute for Health and Care Excellence where possible or published literature otherwise. Deterministic sensitivity, scenario and threshold analyses were conducted. RESULTS: Costs for a single patient treated with PFA were -3% (-£343) less over 12 months than those who received treatment with cryoablation. PFA was associated with 16% higher catheter costs but repeat ablation costs were over 50% less, driven by a reduction in repeat ablations required. Costs of managing complications were -£211 less in total for PFA compared with cryoablation. CONCLUSIONS: Routine adoption of PFA with the pentaspline PFA catheter looks to be as affordable for the NHS as current treatment alternative cryoablation.


Atrial Fibrillation , Catheter Ablation , Cost-Benefit Analysis , Cryosurgery , State Medicine , Atrial Fibrillation/surgery , Atrial Fibrillation/economics , Atrial Fibrillation/therapy , Humans , Cryosurgery/economics , Cryosurgery/methods , United Kingdom , Catheter Ablation/economics , Catheter Ablation/methods , State Medicine/economics
6.
Open Heart ; 11(1)2024 May 09.
Article En | MEDLINE | ID: mdl-38724265

BACKGROUND: Atrial fibrillation (AF), a common, frequently asymptomatic cardiac arrhythmia, is a major risk factor for stroke. Identification of AF enables effective preventive treatment to be offered, potentially reducing stroke risk by up to two-thirds. There is international consensus that opportunistic AF screening is valuable though uncertainty remains about the optimum screening location and method. Primary care has been identified as a potential location for AF screening using one-lead ECG devices. METHODS: A pilot AF screening programme is in primary care in the south of Ireland. General practitioners (GPs) were recruited from Cork and Kerry. GPs invited patients ≥65 years to undergo AF screening. The screening comprised a one-lead ECG device, Kardia Mobile, blood pressure check and ascertainment of smoking status. Possible AF on one-lead ECG was confirmed with a 12-lead ECG. GPs also recorded information including medical history, current medication and onward referral. The Keele Decision Support tool was used to assess patients for oral anticoagulation (OAC). RESULTS: 3555 eligible patients, attending 52 GPs across 34 GP practices, agreed to undergo screening. 1720 (48%) were female, 1780 (50%) were hypertensive and 285 (8%) were current smokers. On the one-lead ECG, 3282 (92%) were in normal sinus rhythm, 101 (3%) had possible AF and among 124 (4%) the one-lead ECG was unreadable or unclassified. Of the 101 patients with possible AF, 45 (45%) had AF confirmed with 12-lead ECG, an incidence rate of AF of 1.3%. Among the 45 confirmed AF cases, 27 (60%) were commenced on OAC therapy by their GP. CONCLUSION: These findings suggest that AF screening in primary care may prove useful for early detection of AF cases that can be assessed for treatment. One-lead ECG devices may be useful in the detection of paroxysmal AF in this population and setting. Current OAC of AF may be suboptimal.


Atrial Fibrillation , Electrocardiography , Mass Screening , Primary Health Care , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/epidemiology , Female , Male , Ireland/epidemiology , Pilot Projects , Primary Health Care/methods , Aged , Mass Screening/methods , Risk Factors , Incidence , Aged, 80 and over , Stroke/prevention & control , Stroke/epidemiology , Stroke/etiology , Predictive Value of Tests
7.
Medicine (Baltimore) ; 103(19): e38079, 2024 May 10.
Article En | MEDLINE | ID: mdl-38728471

Atrial fibrillation (AF) is a prevalent cardiac arrhythmia, with recent research indicating a correlation between immune system characteristics and the development of AF. However, it remains uncertain whether the immunological response is the primary underlying component or a secondary consequence of AF. Initially, we investigated the effect of immune cells on AF by performing forward Mendelian randomization (MR) analyses with immune cells as the exposure variable and their associated genetic variants as instrumental variables. Subsequently, we performed reverse MR analyses with AF as the exposure variable and immune cells as the outcome variable to exclude the interference of reverse causality, to distinguish between primary and secondary effects, and to further elucidate the causal relationship between the immune system and AF. We discovered that membrane proteins on specific immune cells, such as CD25 on memory B cells-which functions as a part of the interleukin-2 receptor-may be risk factors for AF development, with odds ratios of 1.0233 (95% confidence interval: 1.0012-1.0458, P = .0383). In addition, certain immune cell counts, such as the CD4 regulatory T cell Absolute Count, play a protective factor in the development of AF (odds ratio: 0.9513, 95% confidence interval: 0.9165-0.9874; P = .0086). More detailed results are elaborated in the main text. Our MR study has yielded evidence that substantiates a genetically inferred causal association between the immune system and AF. Identifying the risk factors associated with AF is vital to facilitate the development of innovative pharmaceutical treatments.


Atrial Fibrillation , Mendelian Randomization Analysis , Atrial Fibrillation/genetics , Atrial Fibrillation/immunology , Atrial Fibrillation/epidemiology , Humans , Interleukin-2 Receptor alpha Subunit/genetics , Risk Factors , B-Lymphocytes/immunology
8.
EuroIntervention ; 20(9): 591-601, 2024 May 10.
Article En | MEDLINE | ID: mdl-38726722

BACKGROUND: Little is known about the occurrence of subclinical new-onset atrial fibrillation (NOAF) after transcatheter aortic valve implantation (TAVI). AIMS: We aimed to evaluate the incidence, predictors, and clinical impact of subclinical NOAF after TAVI. METHODS: This was a multicentre study, including patients with aortic stenosis (AS) and no previous atrial fibrillation undergoing TAVI, with continuous ambulatory electrocardiogram (AECG) monitoring after TAVI. RESULTS: A total of 700 patients (79±8 years, 49% female, Society of Thoracic Surgeons score 2.9% [1.9-4.0]) undergoing transarterial TAVI were included (85% balloon-expandable valves). AECG was started 1 (0-1) day after TAVI (monitoring time: 14121314 days). NOAF was detected in 49 patients (7%), with a median duration of 185 (43-421) minutes (atrial fibrillation burden of 0.7% [0.3-2.8]). Anticoagulation was started in 25 NOAF patients (51%). No differences were found in baseline or procedural characteristics, except for a higher AS severity in the NOAF group (peak gradient: no NOAF: 71.9±23.5 mmHg vs NOAF: 85.2±23.8 mmHg; p=0.024; mean gradient: no NOAF: 44.4±14.7 mmHg vs NOAF: 53.8±16.8 mmHg; p=0.004). In the multivariable analysis, the baseline mean transaortic gradient was associated with a higher risk of NOAF after TAVI (odds ratio 1.04, 95% confidence interval: 1.01-1.06 for each mmHg; p=0.006). There were no differences between groups in all-cause mortality (no NOAF: 4.7% vs NOAF: 0%; p=0.122), stroke (no NOAF: 1.4% vs NOAF: 2.0%; p=0.723), or bleeding (no NOAF: 1.9% vs NOAF: 4.1%; p=0.288) from the 30-day to 1-year follow-up. CONCLUSIONS: NOAF detected with AECG occurred in 7% of TAVI recipients and was associated with a higher AS severity. NOAF detection determined the start of anticoagulation therapy in about half of the patients, and it was not associated with an increased risk of clinical events at 1-year follow-up.


Aortic Valve Stenosis , Atrial Fibrillation , Electrocardiography, Ambulatory , Transcatheter Aortic Valve Replacement , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/physiopathology , Female , Male , Transcatheter Aortic Valve Replacement/adverse effects , Aged , Aortic Valve Stenosis/surgery , Aged, 80 and over , Electrocardiography, Ambulatory/methods , Risk Factors , Treatment Outcome
9.
BMC Cardiovasc Disord ; 24(1): 246, 2024 May 10.
Article En | MEDLINE | ID: mdl-38730404

BACKGROUND: Clinical outcomes after catheter ablation (CA) or pacemaker (PM) implantation for the tachycardia-bradycardia syndrome (TBS) has not been evaluated adequately. We tried to compare the efficacy and safety outcomes of CA and PM implantation as an initial treatment option for TBS in paroxysmal atrial fibrillation (AF) patients. METHODS: Sixty-eight patients with paroxysmal AF and TBS (mean 63.7 years, 63.2% male) were randomized, and received CA (n = 35) or PM (n = 33) as initial treatments. The primary outcomes were unexpected emergency room visits or hospitalizations attributed to cardiovascular causes. RESULTS: In the intention-to-treatment analysis, the rates of primary outcomes were not significantly different between the two groups at the 2-year follow-up (19.8% vs. 25.9%; hazard ratio (HR) 0.73, 95% confidence interval (CI) 0.25-2.20, P = 0.584), irrespective of whether the results were adjusted for age (HR 1.12, 95% CI 0.34-3.64, P = 0.852). The 2-year rate of recurrent AF was significantly lower in the CA group compared to the PM group (33.9% vs. 56.8%, P = 0.038). Four patients (11.4%) in the CA group finally received PMs after CA owing to recurrent syncope episodes. The rate of major or minor procedure related complications was not significantly different between the two groups. CONCLUSION: CA had a similar efficacy and safety profile with that of PM and a higher sinus rhythm maintenance rate. CA could be considered as a preferable initial treatment option over PM implantation in patients with paroxysmal AF and TBS. TRIAL REGISTRATION: KCT0000155.


Atrial Fibrillation , Bradycardia , Cardiac Pacing, Artificial , Catheter Ablation , Heart Rate , Pacemaker, Artificial , Recurrence , Humans , Male , Female , Middle Aged , Catheter Ablation/adverse effects , Prospective Studies , Treatment Outcome , Aged , Atrial Fibrillation/diagnosis , Atrial Fibrillation/physiopathology , Atrial Fibrillation/therapy , Atrial Fibrillation/surgery , Bradycardia/diagnosis , Bradycardia/therapy , Bradycardia/physiopathology , Cardiac Pacing, Artificial/adverse effects , Time Factors , Risk Factors , Syndrome , Tachycardia/physiopathology , Tachycardia/diagnosis , Tachycardia/therapy , Tachycardia/surgery
10.
Int J Mol Sci ; 25(9)2024 Apr 25.
Article En | MEDLINE | ID: mdl-38731908

In atrial fibrillation (AF), multifactorial pathologic atrial alterations are manifested by structural and electrophysiological changes known as atrial remodeling. AF frequently develops in the context of underlying cardiac abnormalities. A critical mechanistic role played by atrial stretch is played by abnormal substrates in a number of conditions that predispose to AF, including obesity, heart failure, hypertension, and sleep apnea. The significant role of overweight and obesity in the development of AF is known; however, the differential effect of overweight, obesity, cardiovascular comorbidities, lifestyle, and other modifiable risk factors on the occurrence and recurrence of AF remains to be determined. Reverse remodeling of the atrial substrate and subsequent reduction in the AF burden by conversion into a typical sinus rhythm has been associated with weight loss through lifestyle changes or surgery. This makes it an essential pillar in the management of AF in obese patients. According to recently published research, microRNAs (miRs) may function as post-transcriptional regulators of genes involved in atrial remodeling, potentially contributing to the pathophysiology of AF. The focus of this review is on their modulation by both weight loss and catheter ablation interventions to counteract atrial remodeling in AF. Our analysis outlines the experimental and clinical evidence supporting the synergistic effects of weight loss and catheter ablation (CA) in reversing atrial electrical and structural remodeling in AF onset and in recurrent post-ablation AF by attenuating pro-thrombotic, pro-inflammatory, pro-fibrotic, arrhythmogenic, and male-sex-associated hypertrophic remodeling pathways. Furthermore, we discuss the promising role of miRs with prognostic potential as predictive biomarkers in guiding approaches to AF recurrence prevention.


Atrial Fibrillation , Biomarkers , Catheter Ablation , MicroRNAs , Weight Loss , Atrial Fibrillation/metabolism , Atrial Fibrillation/genetics , Atrial Fibrillation/etiology , Humans , MicroRNAs/genetics , MicroRNAs/metabolism , Catheter Ablation/methods , Recurrence , Atrial Remodeling , Animals , Obesity/metabolism , Obesity/complications
11.
Med Sci Monit ; 30: e943526, 2024 May 12.
Article En | MEDLINE | ID: mdl-38734884

BACKGROUND A significant number of atrial fibrillation (AF) recurrences occur after initial ablation, often due to pulmonary vein reconnections or triggers from non-pulmonary veins. MATERIAL AND METHODS Patients with paroxysmal AF who underwent radiofrequency catheter ablation for the first time were enrolled. Base on propensity score matching (1: 1 matching), 118 patients were selected for an optimized workflow for the radiofrequency catheter ablation of paroxysmal AF (OWCA) group and a conventional group. Comparative analysis of the acute and 12-month clinical outcomes was conducted. Moreover, an artificial intelligence analytics platform was used to evaluate the quality of pulmonary vein isolation (PVI) circles. RESULTS PVI was successfully achieved in all patients. Incidence of first-pass isolation of bilateral PVI circles was higher (P=0.009) and acute pulmonary vein reconnections was lower (P=0.027) in the OWCA group than conventional group. The OWCA group displayed a significant reduction in the number of fractured points (P<0.001), stacked points (P=0.003), and a greater proportion of cases in which the radiofrequency index achieved the target value (P=0.003). Additionally, the contact force consistently met the force over time criteria (P<0.001) for bilateral PVI circles in the OWCA group, accompanied by a shorter operation time (P=0.017). During the 12-month follow-up period, the OWCA group exhibited a higher atrial arrhythmia-free survival rate following the initial ablation procedure than did the conventional group. CONCLUSIONS The optimized workflow for radiofrequency catheter ablation of paroxysmal AF could play a crucial role in creating higher quality PVI circles. This improvement is reflected in a significantly elevated 12-month atrial arrhythmia-free survival rate.


Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Workflow , Humans , Atrial Fibrillation/surgery , Catheter Ablation/methods , Female , Male , Middle Aged , Treatment Outcome , Pulmonary Veins/surgery , Aged , Propensity Score , Recurrence
12.
J Med Vasc ; 49(2): 80-89, 2024 Apr.
Article En | MEDLINE | ID: mdl-38697714

INTRODUCTION AND AIM: The advances and the wide use of brain imaging have considerably increased the prevalence of silent brain infarctions (SBI). We aim in this study to determine the prevalence of SBI in patients presenting with acute cardioembolic stroke and the predictive cardiovascular risk factors. METHODS: This retrospective study included 267 patients presenting with acute cardioembolic stroke in the emergency and/or neurology departments of the Hassan II University Hospital Center. Clinical, biological and echocardiographic characteristics were recorded. All patients were screened for SBI by brain imaging. RESULTS: The prevalence of SBI in our series was 46%. A group of 203 non-valvular patients and a group of 64 valvular patients were distinguished. In non-valvular group, the average age was 72.97±10.53years. The prevalence of SBI was 45.3%. Forty-four percent of patients with SBI had atrial fibrillation (AF). In multivariate regression analysis, the history of previous stroke, CHA2DS2-VASc Score≥4, enlarged left atrium (LA), the association of AF with enlarged LA and the lability of International Normalized Ratio in patients initially treated with anticoagulants were significantly associated with the occurrence of SBI (P=0.013, P=0.032, P=0.0001, P=0.01, P=0.03, respectively). Territorial location was significantly the most frequent (P=0.007). In valvular group, the average age was 57.19±14.38years. The prevalence of SBI was 48.4%. In multivariate regression analysis, SBI were significantly associated with moderate or severe mitral stenosis (P=0.02) and with the enlarged LA (P=0.02). In all patients, Modified Rankin Scale at 3 months of discharge from the acute stroke was significantly higher (mRS≥3) in patients with SBI (P=0.04). CONCLUSIONS: SBI requires good management of associated cardiovascular risk factors in a population presenting with initial cardioembolic stroke.


Brain Infarction , Embolic Stroke , Humans , Male , Female , Retrospective Studies , Aged , Middle Aged , Prevalence , Embolic Stroke/epidemiology , Embolic Stroke/etiology , Embolic Stroke/diagnostic imaging , Risk Factors , Aged, 80 and over , Brain Infarction/epidemiology , Brain Infarction/diagnostic imaging , Brain Infarction/etiology , Asymptomatic Diseases , Multivariate Analysis , Atrial Fibrillation/epidemiology , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis
13.
Open Heart ; 11(1)2024 May 08.
Article En | MEDLINE | ID: mdl-38719499

OBJECTIVE: Implantable loop recorders (ILRs) are increasingly used for long-term rhythm monitoring after ischaemic and cryptogenic stroke, with the goal of detecting atrial fibrillation (AF) and subsequent initiation of oral anticoagulation to reduce risk of adverse clinical outcomes. There is a need to determine the effectiveness of different rhythm monitoring strategies in this context. METHODS: We conducted a retrospective cohort analysis of individuals with commercial and Medicare Advantage insurance in Optum Labs Data Warehouse who had incident ischaemic or cryptogenic stroke and no prior cardiovascular implantable electronic device from 1 January 2016 to 30 June 2021. Patients were stratified by rhythm monitoring strategy: ILR, long-term continuous external cardiac monitor (>48 hours to 30 days) or Holter monitor (≤48 hours). The primary outcome was risk-adjusted all-cause mortality at 12 months. Secondary outcomes included new diagnosis of AF and oral anticoagulation, bleeding, and costs. RESULTS: Among 48 901 patients with ischaemic or cryptogenic stroke, 9235 received an ILR, 29 103 long-term continuous external monitor and 10 563 Holter monitor only. Mean age was 69.9 (SD 11.9) years and 53.5% were female. During the 12-month follow-up period, patients who received ILRs compared with those who received long-term continuous external monitors had a higher odds of new diagnosis of AF and oral anticoagulant initiation (adjusted OR 2.27, 95% CI 2.09 to 2.48). Compared with patients who received long-term continuous external monitors, those who received ILRs had similar 12-month mortality (HR 1.00; 95% CI 0.89 to 1.12), with approximately $13 000 higher costs at baseline (including monitor cost) and $2500 higher costs during 12-month follow-up. CONCLUSIONS: In this large real-world study of patients with ischaemic or cryptogenic stroke, ILR placement resulted in more diagnosis of AF and initiation of oral anticoagulation, but no difference in mortality compared with long-term continuous external monitors.


Atrial Fibrillation , Electrocardiography, Ambulatory , Ischemic Stroke , Humans , Female , Male , Aged , Retrospective Studies , Electrocardiography, Ambulatory/instrumentation , Electrocardiography, Ambulatory/economics , Electrocardiography, Ambulatory/methods , Ischemic Stroke/economics , Ischemic Stroke/mortality , Ischemic Stroke/diagnosis , Ischemic Stroke/prevention & control , Ischemic Stroke/etiology , Atrial Fibrillation/diagnosis , Atrial Fibrillation/economics , Atrial Fibrillation/drug therapy , Atrial Fibrillation/complications , Atrial Fibrillation/mortality , United States/epidemiology , Anticoagulants/economics , Anticoagulants/administration & dosage , Time Factors , Middle Aged , Follow-Up Studies , Cost-Benefit Analysis , Aged, 80 and over , Health Care Costs
14.
J Med Case Rep ; 18(1): 235, 2024 May 02.
Article En | MEDLINE | ID: mdl-38698496

BACKGROUND: Amiodarone-induced thyroid dysfunction (AIT) is a side-effect associated with the use of Amiodarone for the treatment of refractory arrythmias. Resulting hyperthyroidism can precipitate cardiac complications, including cardiac ischemia and myocardial infarction, although this has only been described in a few case reports. CASE PRESENTATION: We present here a clinical scenario involving a 66-year-old male Caucasian patient under Amiodarone for atrial fibrillation, who developed AIT. In the presence of dyspnea, multiple cardiovascular risk factors and ECG abnormalities, a transthoracic echocardiogram was performed, showing inferobasal hypokinesia. This led to further investigations through a cardiac PET-CT, where cardiac ischemia was suspected. Ultimately, the coronary angiography revealed no abnormalities. Nonetheless, these extensive cardiologic investigations led to a delay in initiating an emergency endovascular revascularization for acute-on-chronic left limb ischemia. Although initial treatment using Carbimazole was not successful after three weeks, the patient reached euthyroidism after completion of the treatment with Prednisone so that eventually thyroidectomy was not performed. Endovascular revascularization was finally performed after more than one month. CONCLUSIONS: We discuss here cardiac abnormalities in patients with AIT, which may be due to relative ischemia secondary to increased metabolic demand during hyperthyroidism. Improvement of cardiac complications is expected through an optimal AIT therapy including medical therapy as the primary approach and, when necessary, thyroidectomy. Cardiac investigations in the context of AIT should be carefully considered and may not justify delaying other crucial interventions. If considered mandatory, diagnostic procedures such as coronary angiography should be preferred to functional testing.


Amiodarone , Anti-Arrhythmia Agents , Myocardial Ischemia , Humans , Amiodarone/adverse effects , Male , Aged , Anti-Arrhythmia Agents/adverse effects , Myocardial Ischemia/chemically induced , Atrial Fibrillation/drug therapy , Positron Emission Tomography Computed Tomography , Hyperthyroidism/complications , Hyperthyroidism/drug therapy , Echocardiography
15.
Europace ; 26(5)2024 May 02.
Article En | MEDLINE | ID: mdl-38696675

AIMS: Contact force (CF)-sensing radiofrequency (RF) catheters with an ablation index have shown reproducible outcomes for the treatment of atrial fibrillation (AF) in large multicentre studies. A dual-energy (DE) focal CF catheter to deliver RF and unipolar/biphasic pulsed field ablation (PFA), integrated with a three-dimensional (3D) mapping system, can provide operators with additional flexibility. The SmartfIRE study assessed the safety and efficacy of this novel technology for the treatment of drug-refractory, symptomatic paroxysmal AF. Results at 3 months post-ablation are presented here. METHODS AND RESULTS: Pulmonary vein isolation (PVI) was performed using a DE focal, irrigated CF-sensing catheter with the recommendation of PFA at posterior/inferior and RF ablation at the anterior/ridge/carina segments. Irrespective of energy, a tag size of 3 mm; an inter-tag distance ≤6 mm; a target index of 550 for anterior, roof, ridge, and carina; and a target index of 400 for posterior and inferior were recommended. Cavotricuspid isthmus ablation was permitted in patients with documented typical atrial flutter. The primary effectiveness endpoint was acute procedural success. The primary safety endpoint was the rate of primary adverse events (PAEs) within 7 days of the procedure. A prespecified patient subset underwent oesophageal endoscopy (EE; 72 h post-procedure), neurological assessment (NA; pre-procedure and discharge), and cardiac computed tomography (CT)/magnetic resonance angiogram (MRA) imaging (pre-procedure and 3 months post-procedure) for additional safety evaluation, and a mandatory remapping procedure (Day 75 ± 15) for PVI durability assessment. Of 149 patients enrolled between February and June 2023, 140 had the study catheter inserted (safety analysis set) and 137 had ablation energy delivered (per-protocol analysis set). The median (Q1/Q3) total procedure and fluoroscopy times were 108.0 (91.0/126.0) and 4.2 (2.3/7.7) min (n = 137). The acute procedural success rate was 100%. First-pass isolation was achieved in 89.1% of patients and 96.8% of veins. Cavotricuspid isthmus ablations were successfully performed in 12 patients [pulsed field (PF) only: 6, RF only: 5, and RF/PF: 1]. The PAE rate was 4.4% [6/137 patients; 2 pulmonary vein (PV) stenoses, 2 cardiac tamponades/perforations, 1 stroke, and 1 pericarditis]. No coronary artery spasm was reported. No oesophageal lesion was seen in the EE subset (0/31, 0%). In the NA subset (n = 30), microemboli lesions were identified in 2 patients (2/30, 6.7%), both of which were resolved at follow-up; only 1 was symptomatic (silent cerebral lesion, 3.3%). In the CT/MRA subset (n = 30), severe PV narrowing (of >70%) was detected in 2 patients (2/30, 6.7%; vein level 2/128, 1.6%), of whom 1 underwent dilatation and stenting and 1 was asymptomatic; both were associated with high index values and a small inter-tag distance. In the PV durability subset (n = 30), 100/115 treated PVs (87%) were durably isolated and 18/30 patients (60.0%) had all PVs durably isolated. CONCLUSION: A DE focal CF catheter with 3D mapping integration showed a 100% acute success rate with an acceptable safety profile in the treatment of paroxysmal AF. Prespecified 3-month remapping showed notable PVI durability. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT05752487.


Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Pulmonary Veins/surgery , Atrial Fibrillation/surgery , Atrial Fibrillation/physiopathology , Male , Female , Catheter Ablation/methods , Catheter Ablation/instrumentation , Middle Aged , Treatment Outcome , Aged , Imaging, Three-Dimensional , Cardiac Catheters , Time Factors , Equipment Design , Prospective Studies , Recurrence
17.
BMC Med ; 22(1): 194, 2024 May 13.
Article En | MEDLINE | ID: mdl-38735916

BACKGROUND: The reason for higher incidence of atrial fibrillation (AF) in Europe compared with East Asia is unclear. We aimed to investigate the association between modifiable lifestyle factors and lifetime risk of AF in Europe and East Asia, along with race/ethnic similarities and disparities. METHODS: 1:1 propensity score matched pairs of 242,763 East Asians and 242,763 White Europeans without AF were analyzed. Modifiable lifestyle factors considered were blood pressure, body mass index, cigarette smoking, diabetes, alcohol consumption, and physical activity, categorized as non-adverse or adverse levels. Lifetime risk of AF was estimated from the index age of 45 years to the attained age of 85 years, accounting for the competing risk of death. RESULTS: The overall lifetime risk of AF was higher in White Europeans than East Asians (20.9% vs 15.4%, p < 0.001). The lifetime risk of AF was similar between the two races in individuals with non-adverse lifestyle factor profiles (13.4% vs 12.9%, p = 0.575), whereas it was higher in White Europeans with adverse lifestyle factor profiles (22.1% vs 15.8%, p < 0.001). The difference in the lifetime risk of AF between the two races increased as the burden of adverse lifestyle factors worsened (1 adverse lifestyle factor; 4.3% to ≥ 3 adverse lifestyle factors; 11.2%). Compared with East Asians, the relative risk of AF in White Europeans was 23% and 62% higher for one (hazard ratio [HR] 1.23, 95% confidence interval [CI] 1.16-1.29) and ≥ 3 adverse lifestyle factors (HR 1.62, 95% CI 1.51-1.75), respectively. CONCLUSIONS: The overall higher lifetime risk of AF in White Europeans compared with East Asians might be attributable to adverse lifestyle factors. Adherence to healthy lifestyle factors was associated with the lifetime risk of AF of about 1 in 8 regardless of race/ethnicity.


Atrial Fibrillation , Life Style , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Atrial Fibrillation/epidemiology , Biological Specimen Banks , Cohort Studies , Longitudinal Studies , Republic of Korea/epidemiology , Risk Factors , UK Biobank , United Kingdom/epidemiology , White People , East Asian People
18.
Trials ; 25(1): 317, 2024 May 14.
Article En | MEDLINE | ID: mdl-38741218

BACKGROUND: Surgical left atrial appendage (LAA) closure concomitant to open-heart surgery prevents thromboembolism in high-risk patients. Nevertheless, high-level evidence does not exist for LAA closure performed in patients with any CHA2DS2-VASc score and preoperative atrial fibrillation or flutter (AF) status-the current trial attempts to provide such evidence. METHODS: The study is designed as a randomized, open-label, blinded outcome assessor, multicenter trial of adult patients undergoing first-time elective open-heart surgery. Patients with and without AF and any CHA2DS2-VASc score will be enrolled. The primary exclusion criteria are planned LAA closure, planned AF ablation, or ongoing endocarditis. Before randomization, a three-step stratification process will sort patients by site, surgery type, and preoperative or expected oral anticoagulation treatment. Patients will undergo balanced randomization (1:1) to LAA closure on top of the planned cardiac surgery or standard care. Block sizes vary from 8 to 16. Neurologists blinded to randomization will adjudicate the primary outcome of stroke, including transient ischemic attack (TIA). The secondary outcomes include a composite outcome of stroke, including TIA, and silent cerebral infarcts, an outcome of ischemic stroke, including TIA, and a composite outcome of stroke and all-cause mortality. LAA closure is expected to provide a 60% relative risk reduction. In total, 1500 patients will be randomized and followed for 2 years. DISCUSSION: The trial is expected to help form future guidelines within surgical LAA closure. This statistical analysis plan ensures transparency of analyses and limits potential reporting biases. TRIAL REGISTRATION: Clinicaltrials.gov, NCT03724318. Registered 26 October 2018, https://clinicaltrials.gov/study/NCT03724318 . PROTOCOL VERSION: https://doi.org/10.1016/j.ahj.2023.06.003 .


Atrial Appendage , Atrial Fibrillation , Cardiac Surgical Procedures , Multicenter Studies as Topic , Randomized Controlled Trials as Topic , Stroke , Humans , Atrial Appendage/surgery , Atrial Fibrillation/surgery , Atrial Fibrillation/complications , Stroke/prevention & control , Stroke/etiology , Cardiac Surgical Procedures/adverse effects , Risk Factors , Treatment Outcome , Risk Assessment , Data Interpretation, Statistical , Ischemic Attack, Transient/prevention & control , Ischemic Attack, Transient/etiology , Male , Female , Left Atrial Appendage Closure
19.
Rev. neurol. (Ed. impr.) ; 78(9)1-15 may 2024. tab, graf
Article Es | IBECS | ID: ibc-CR-367

Introducción El ictus isquémico agudo es una de las principales causas globales de morbimortalidad. La trombectomía mecánica ha mejorado el pronóstico funcional de esta patología; sin embargo, la transformación hemorrágica es una complicación frecuente. La tomografía computarizada (TC) de tecnología espectral, como prueba de neuroimagen de control, diferencia la extravasación de contraste de la transformación hemorrágica gracias al diferente comportamiento de los materiales a la energía dual, y esta distinción es de utilidad en su manejo clinicoterapéutico. Material y métodos. Estudio unicéntrico, observacional y retrospectivo, en el cual se investigó, mediante el acceso a una base de datos disociada y a la historia clínica, la presencia de una serie de variables clínicas, radiológicas y terapéuticas en los pacientes con ictus isquémico agudo que fueron tratados con trombectomía mecánica en nuestro hospital entre julio de 2022 y marzo de 2023.ResultadosDe los 155 pacientes incluidos, se realizó una TC craneal espectral en 63 y convencional en 75. En el grupo de TC espectral se detectaron 21 imágenes hiperdensas y en el grupo de TC convencional fueron 28. En el 42,8% de los casos en los que se detectó una hiperdensidad en el grupo de TC convencional no se pudo distinguir entre extravasación de contraste y transformación hemorrágica, en comparación con el 4,8% del grupo de TC espectral (p < 0,001).ConclusionesLa TC espectral confiere una gran confianza diagnóstica al radiólogo para establecer el tipo de hiperdensidad detectada y, por ello, proporciona también una gran confianza terapéutica al neurólogo para reiniciar precozmente la anticoagulación. (AU)


Introduction. Acute ischemic stroke is one of the leading global causes of morbidity and mortality. Mechanical thrombectomy has improved the functional prognosis of this condition; however, hemorrhagic transformation is a common complication. Spectral computed tomography (CT) imaging, as a neuroimaging control test, distinguishes contrast extravasation from hemorrhagic transformation due to the differential behavior of materials at dual energy levels. This distinction is valuable in its clinical therapeutic management.Material and methods. A single-center, observational, retrospective study was conducted in which the presence of various clinical, radiological, and therapeutic variables in patients with acute ischemic stroke treated with mechanical thrombectomy at our hospital between July 2022 and March 2023 was investigated using access to a dissociated database and medical records.Results. Out of 155 included patients, spectral cranial CT was performed in 63, and conventional cranial CT in 75. In the spectral CT group, 21 hyperdense images were detected, compared to 28 in the conventional CT group. In 42.8% of cases where hyperdensity was detected in the conventional CT group, it was not possible to distinguish between contrast extravasation and hemorrhagic transformation, in contrast to the 4.8% in the spectral CT group (p < 0.001).Conclusions. Spectral CT provides high diagnostic confidence to the radiologist in identifying the type of detected hyperdensity, thereby offering significant therapeutic confidence to the neurologist in early resuming anticoagulation therapy. (AU)


Humans , Tomography, X-Ray Computed , Thrombectomy , Atrial Fibrillation
...